振动声桥圆窗植入术的研究进展

邹哲飞;华清泉;

1:武汉人民医院耳鼻咽喉-头颈外科

摘要
<正>目前传统的助听器仍然是听力损失患者最常见的选择,但其有时存在如堵耳效应、啸叫、言语声失真及高频听力增益不足等问题,有些外耳道畸形或其他病变的患者无法佩戴助听器。为此,各种相继问世的植入式助听器备受医生和患者的关注。振动
关键词
基金项目(Foundation):
作者
邹哲飞;华清泉;
参考文献

1 Needham AJ,Jiang D,Bibas A,et al.The effects of mass load-ing the ossicles with a floating mass transducer on middle ear transfer function[J].Otol Neurotol,2005,2:218.

2 Arnold A,Stieger C,Candreia C,et al.Factors improving the vibration transfer of the floating mass transducer at the round window[J].Otol Neurotol,2010,31:122.

3 Snik AF,Cremers CW.First audiometric results with the vi-brant soundbridge,a semi—implantable hearing device for sen-sorineural hearing loss[J].Audiology,1999,38:335.

4 Hough JV,Dyer RK,Matthews P,et al.Semi—implantable e-lectromagnetic middle ear hearing device for moderate to severe sensorineural hearing loss[J].Otolaryngol Cin North Am,200l,34:401.

5 Cremers CW,O'Connor AF,Helms J,et al.International consen-sus on vibrant soundbridge implantation in children and adolescents[J].Int J Pediatr Otorhinolaryngol,2010,74:1 267.

6 Foytd C,Arfrae M.Minimal access surgery for the Sympho—nix/Med—E1vibrant soundbridge middle ear hearing implant[J].Otol Neurotol,2006,27:167.

7 Gan RZ,Wood MW,Ball GR.Implantable hearing device per-formance measured by laser doppler interferometry[J].Ear Nose Throot J,1997,76:297.

8 Rajan GP,Lampacher P,Ambett R,et al.Impact of floating mass transducer coupling and positioning in round window vi-broplasty[J].Otol Neurotol,2011,32:271.

9 Arnold A,Kompis M,Candreia C,et al.The floating mass transducer at the round window:direct transmission or bone conduction[J]?Hear Res,2010,263:120.

10 Sterkers O,Boucarra DI,Abassi S,et al.A middle ear im-plant,the symphonix vibrant soundbridge:retrospective study of the first 1 2 5patients implanted in France[J].Otol Neurot01,2003,3:427.

11 Dazert S,Shehats—Dieler WE,Diei ERR,et al.“Vibrant soundbridge”middle ear implant forauditory rehabilitation in sensory hearing loss.I.Clinical aspects,indications and ini-tial results[J].Laryngorhinootologie,2000,79:459.

12 Verhaegen VJ,Mulder JJ,Noten JF,et al.Intraoperative audito-ry steadystate response measurements during vibrant soundbridge middle ear implantation in patients with mixed hearing loss:pre-liminary results[J].Otol Neurotol,2010,31:1 365.

13 Nakajima HH,Dong W,Olson ES,et al.Evaluation of round window stimulation using the floating mass transducer by intracochlear sound pressure measurements in human tem-poral bones[J].Otol Neurotol,2010,31:506.

14 Todt I,Seidl RO,Ernst A.Hearing benefit of patients after vibrant soundbride implantation[J].ORL,2005,67:203.

15 Jan K,Wolfgang A,Rainre S.Round window stimulation with an implantable hearing aid combined with autogenous recon-struction of the auricle-a new approach[J].ORL J Otorhi-nolaryngol Relat Spec,2006,68:378.

16 Colletti V,Soli SD,Carner M,et al.Treatment of mixed hearing loss via implantation of a vibratory transducer on the round window[J].Int J Audiol,2006,45:600.

17 Streitberger C,Perotti M,Beltrame MA,et al.Vibrant sound-bridge for hearing restoration after chronic ear surgery[J].Rev Laryngol Otol Rhinol(Bord),2009,130:83.

18 Colletti V,Carner M,Colletti L.TORP vs round window im-plant for hearing restoration of patients with extensive ossic-ular chain defect[J].Acta Otolaryngol,2009,129:449.

19 Shimizu Y,Puria S,Goode RL.The floating mass transducer on the round window versus attachment to an ossicular re-placement prosthesis[J].Otol Neurotol,2011,32:98.

本文信息

PDF(85K)

本文关键词相关文章

本文作者相关文章

邹哲飞华清泉