目的探讨纯音测听上升法与下降法对感音神经性听力损失患者舒适阈、不适阈的影响。方法对57名(111耳)感音神经性听力损失患者进行纯音测试测得听阈,然后随机将受试者分为两组,进行1 000 Hz纯音舒适阈测试。一组受试者先用上升法(ascending)测试其舒适阈,再进行下降法测试;另一组则相反,最后进行不适阈测试。分别比较两组以上升-下降法测得的MCL之差值(A-D差)。结果轻度听力损失患者平均MCL为64.83±7.82 dB HL,A-D差为5.67±5.94 dB,平均UCL为94.67±8.76 dB HL;中度听力损失患者平均MCL为66.56±8.80 dB HL,A-D差为5.75±4.32 dB,平均UCL为91.60±9.84 dB HL;中重度听力损失患者平均MCL为77.15±9.56 dB HL,A-D差为4.86±4.22 dB,平均UCL为98.89±9.11 dB HL;重度听力损失平均MCL为89.64±8.65 dB HL,A-D差为3.57±4.76 dB,平均UCL为106.43±9.00 dB HL。结论听力损失程度越重,MCL、UCL越高。上升法较下降法测得的MCL低。
关键词
感音神经性听力损失;舒适阈;不适阈;上升法;下降法
基金项目(Foundation):
作者
胡旭君;黄方园;
参考文献

1 Gelfanel SA.Essentional of Audiology[M].New York:Thiemesecond edition,2001.266~267.

2王永华,郑日新.耳聋[M].合肥:安徽科学技术出版社,2001.2~4.

3 Cox RM.Using loudness data for hearing aid selection:TheI HAFF approach[J].The Hearing Journal,1995,48:10,39.

4 Shapiro I.Comparison of three hearing aid prescription proce-dures[J].Ear and Hearing,1980,1:211.

5 Byrne D.Effects of bandwidth and sti mulus type on most com-fortable loudness levels of hearing-i mpaired listeners[J].Journal of the Acoustical Society of America,1987,80:484.

6 Ventry I M,Johnson JI.Evaluation of a clinical methodfor measur-ing comfortable loudness for speech[J].Journal of Speech andHearing Disorders,1978,43:149.

7 Dillon H.Prescribing hearing aid performance[M].In:Hear-ing aids.New York:Thieme,2001.234~280.

8 Munro KJ,Patel RK.Are clinical measurements of uncomfort-able loudness levels a validindicator of real world auditory dis-comfort[J].British Journal of Audiology,1998,32:287.

9 Kamm CA,Dirks DD,Mickey MR.Effect of sensorineural hearingloss on loudness discomfort level and most comfortable loudnessjudgments[J].Journal of Speech and Hearing Research,1978,21:668.

10 Sammeth CA,Birman M,Hecox KE.Variability of most com-fortable and uncomfortable loudness levels to speech sti muliin the hearingi mpaired[J].Ear and Hearing,1989,10:94.

11 Bauman N,Ventry I M.Effect of a pretest listening exposureon the ascending descending gap at most comfortableloudnesslevels[J].Ear and Hearing,1983,4:102.

12 Punch J,Joseph A,Rakerd B.Most comfortable and uncom-fortable loudnesslevels:six decades of research[J].AmericanJournal of Audiology,2004,13:144.

13邢光前,陈智斌.老年聋的研究进展[J].实用老年医学,2008,22:86.

14 Beattie RC,Svihovec DA,Carmen RE,et al.Loudness dis-comfort level for speech:Comparison of twoinstructional setsfor saturation sound pressure level selection[J].Ear andHearing,1980,1:197.

本文信息

PDF(100K)

本文作者相关文章

胡旭君黄方园