1000Hz探测音声导抗检查在新生儿听力筛查中的应用价值

Application Value of 1000Hz High Frequency Immitance Test in Newborn Hearing Screening

姚寿国;史波宁;陈淑飞;顾黎黎;

1:宁波大学医学院附属医院听觉与平衡医学中心

摘要
目的探讨1 000 Hz探测音声导抗检查在听力筛查未通过新生儿听力评估中的作用。方法回顾性分析2018年1月至2019年12月期间新生儿听力筛查未通过的531例(820耳)婴儿的临床资料,其中DPOAE及AABR均未通过者337例527耳为A组,DPOAE未通过但AABR通过者192例289耳为B组,DPOAE通过但AABR未通过者2例4耳为C组,以DPOAE及AABR均通过的1 000例(2 000耳)为对照组(D组),对四组新生儿行1 000 Hz探测音声导抗测试,分析各组Ya图形态及分型。结果四组1 000 Hz声导抗检查Ya图分型比较有显著差异,A组和B组异常率(分别为95.07%和85.81%)显著高于对照组(1.16%.),差异有统计学意义(P<0.05),C组2例4耳均为正常型。结论对新生儿听力初筛或复筛未通过的新生儿,再采用1 000 Hz探测音声导抗检查可早期判断新生儿中耳功能,降低DPOAE及AABR听力筛查的假阳性率。
关键词
新生儿;听力筛查;1000Hz探测音;声导抗检查
基金项目(Foundation):
作者
姚寿国;史波宁;陈淑飞;顾黎黎;
参考文献

1 Wroblewska-Seniuk KE,Dabrowski P,Szyfter W,et al.Universal newborn hearing screening - methods and results,obstacles and benefits newborn hearing screening[J].Pediatr Res,2016,81:415.

2 ChenJL.Newbornhearing screening may predict eustachiantube dysfunction[J].Int J Pediatr Otorhinolaryngol,2015,79:2099.

3 Ohmori S,Sugaya A,Toida N,et al、Does the introduction of newborn hearing screening improve vocabulary development in hearing-impaired children?A population-based study in Japan[J].Int J PediatrOtorhinolaryngol,2015,79:196.

4 Ngui LX,Tang IG,Prepageran N,et al.Comparison of distortion product otoacoustic emission (DPOAE) and automated auditory brainstem response (AABR) for neonatal hearing screening in a hospital with high delivery rate[J].Int J Pediatr Otorhinolaryngol,2019,120:184.

5 Yang HC,Sung CM,Shin DJ,et al.Newborn hearing screening in prematurity:fate of screening failures and auditory maturation[J].Clin Otolaryngol,2017,42:661.

6 杨花荣,延青,刘妮,等,听力学检查结果预测新生儿听力损失程度及类型的研究[J].中国实验诊断学,2018,22:801.

7 de Lyra-Silva KA,Sanches SGG.Middle ear muscle reflex measurement in neonates:comparison between 1000cHz and 226Hz probe tones[J].Int J Pediatr Otorhinolaryngol,2015,79:1510.

8 Ravi R,Gunjawate DR,Yerraguntla K,et al.Follow-up in newborn hearing screening-a systematic review[J].Int J Pediatr Otorhinolaryngol,2016,90:29.

9 杨奉玲,王彪,余文兴,等,不同月龄婴儿1 000 Hz及226 Hz探测音的声反射分析[J].听力学及言语疾病杂志,2018,26:261.

10 姜岚,张可,韩富根.DPOAE未通过新生儿声导抗与耳镜检查结果分析[J].中华耳科学杂志,2015,13:667.

11 Cubillana-Herrero JD,Pelegrín-Hernández JP,Soler-Valcarcel A,et al.The assessment of the newborn hearing screening program in the region of murcia from 2004 to 2012[J].Int J Pediatr Otorhinolaryngol,2016,88:228.

12 阮小微,林霖,王涛.基于FPGA的多频耳声导抗测试系统的设计[J].现代电子技术,2018,41:63.

13 薛卫艳.联合应用DPOAE和耳声发射检测84例小月龄婴儿[J].中国听力语言康复科学杂志,2015,13:120.

14 孙婧,赵正言,付勇,等.0~12月龄婴幼儿不同频率声导抗测试研究[J].中华耳科学杂志,2015,13:428.

15 苏仁杰,许军,陈淑飞,等.1~6月龄分泌性中耳炎患儿多频声导纳诊断研究 [J].听力学及言语疾病杂志,2013,21:585.